Ventilation type aging testing chamber

Product introduction:

Ventilation type aging testing chamber was used to measure the performance of the sample in the air under simulated high temperature and atmospheric pressure


protective device:
Test space temperature fuse
Fan motor overheated
Over temperature
Overall equipment phase / reverse phase
Overall equipment timing
Leakage Protection
The power distribution control cabinet opens the power failure protection
Automatic shutdown after fault alarm



Corresponding standard

Accord with ASTM D5423-9(R2005)(Ⅱ-Type oven)and ASTMD 5374-93(2005) UL-1581、GB、VDE、JIS、IEC 


Applicable industries

The aging tank used to test the material heat-resisting for polymer materials (plastics, plastic) and electrical insulation materials, such as: wire and cable sheathing, heat-shrinkable tubing, rubber or PVC materials.


Main parameters:

Model:HD-E701

Testing space:About 45×50×45cm

Temperature:RT~200℃,resolution: 0.1℃,accuracy: 0.5℃

Rotation:0~10 or 10~200 time/H

Ventilation adjusted:Auto-tuning type

Ventilation system:Using voltage regulator to change the volume of air, convenient to adjust

Built-in circulating air system:ensure the temperature uniformly:1%(count at the highest temperature)

Material:SUS#304 stainless steel

Protector:Over-temperature breaker

control system:

1. TCM control system can make the amount of increase heat is equal   to heat of los

2. With P.I.D automatic calculation function, precision temperature control

sensor:high-accuracy PT100 thermocouple。temperature fluctuation 0.5%(count at the highest temperature)

inside size:50cm(L)x 40 cm(D)x 50 cm(H)

outside size:120cm(L)x 65 cm(D)x 134 cm(H)

insulation:80mm rock wool

Count the volume of air:Formula for Japan JIS7212 N = 3590(X-Y)

X: the consumption of electricity in ventilation WH。

Y: the consumption of electricity in no ventilation WH。     

V: volume (cm3)

D: Density of air(g/cm3)

T: temperature contrast between inside and outside