Gas Chromatography
Gas Chromatography
Gas Chromatography
Product Description:
The gas chromatograph is used for quantitative and qualitative analysis to determine the physical and chemical constants such as the distribution coefficient, activity coefficient, molecular weight and surface area of the sample in the fixed phase. An instrument for analyzing the components of a mixed gas.
Gas chromatograph is fully realized keystrokes, large screen LCD liquid crystal display, display intuitive, easy to operate, is a new generation of domestic gas chromatograph, price excellent, low prices, excellent performance, reliable operation.
Application industry
1. Analysis of dissolved gas in transformer oil;
2. Analysis of ethylene oxide in medical devices.
3. Analysis of coke oven gas;
4. Pesticide residue analysis;
Alcohol analysis in blood; 5.
6. Analysis of natural gas and liquefied gas;
7. Indoor environment TVOC analysis;
8. Analysis of liquor components;
9. High purity gas analysis;
10. Detection of solvent residue of packaging materials.
Form a complete set of products
Headspace sampler, gas generator, gas purifier, thermal analyzer, pyrolyzer, etc.
Technical indicators
Temperature control | |
Temperature control range | Indoor temperature+7℃~400℃(Incremental 0.1℃) |
Program warming | 13th stage |
Program heating rate | 0.1℃~50℃/min(Incremental0.1℃) |
Detectors | |
Hydrogen Flame Ionization detector(FID) | |
Detection limit | ≤5×10-12g/s(16 alkanes) |
Linear range | ≥107 |
Baseline noise | ≤6×10-12A/H |
Stable time | ≤20min |
Thermal conductivity Pool Detector(TCD) | |
Sensitivity | ≥10000mV·ml/mg(16 alkanes) |
Baseline noise | ≤16μV(Carrier Gas for99.999Hydrogen) |
Flame Photometric detectors(FPD) | |
Detection limit | ≤6×10-13g/s(P)≤5×10-11g/s(P)(Parathion methyl) |
Baseline noise | ≤2×10-13A/H |
Electronic capture Detectors(ECD) | |
Maximum operating temperature | 350℃ |
Detection limit | ≤5x10-14g/ml(r-666) |
Baseline noise | ≤20μV |
Nitrogen and phosphorus detectors(NPD) | |
Detection limit | ≤1×10-12g/s(N)(Azo benzene) ≤5×10-13g/s(N)(Malathion) |
Baseline noise | ≤2×10-13A/H |
The table parameters is for the company Standard Model parameters, we support customer customization parameters