Hot And Cold Temperature Thermal Shock Environmental Test Chamber
Description:
Thermal shock chamber is divided into high temperature area, low temperature area and test area three parts, each area is a unique insulation structure, so doing hot and cold impact test. High-temperature impact test or low-temperature impact test, the maximum time is up to 9999 minutes, the most cycle time is up to 9999 times. The machine can be automatically or manually cycle the impact or selectively set the two areas or three areas to impact of hot and cold. It used binary cooling system that is very effectiveness for cooling, the cooling system is divided into the air-cooled and water-cooled. It also can be connected with a computer, but the record instrument is only for optional purchase. Color LCD touch-control operation interface with Chinese and English, easy to operate.
Notes
1. If the high-temp exposure range lower limit + 60°C is required or the low temp exposure range lower limit -60°C, please select the “ambient-temperature exposure” option
2. If the temp fluctuation need to below ±1.8°C please select the “Low temp fluctuation package”
3. Temperature heat-up/pull down time are applicable only during independent chamber operation
4. If the automatically operated sliding door required, please select the “Automatically door package”
5. Air-cooled condenser / Water-cooled condenser both available
6. Apply on water-cooled condenser only
Standard features
System | Two-zone test by means of damper switching | |||||||
Three-zone chamber | ||||||||
Model | HD-E703-50A/HD-E703-50W | HD-E703-100A/HD-E703-100W | Customized | |||||
Performance | Test area | High temp. exposure range*1 | +60~ to +200°C | |||||
Low temp. exposure range*1 | -65to 0 °C | |||||||
Temp. fluctuation *2 | ±1.8°C | |||||||
Hot chamber | Pre-heat upper limit | +200°C | ||||||
Temp. heat up time*3 | Ambient temp. to +200°C within 30min | |||||||
Cold chamber | Pre-cool lower limit | -65°C | ||||||
Temp. pull down time*3 | Ambient temp. to -65°C within 70min | |||||||
Temp. recovery (2-zone) | Recovery conditions | Two-zone: High temp. exposure +125°C 30 min, Low temp. exposure -40°C 30 min; Specimen 6.5 kg (specimen basket 1.5kg) | ||||||
Temp. recovery time | Within 10 min. | |||||||
Construction | External material | Cold-rolled rust-proofed steel plate | ||||||
Test area material | SUS304 stainless steel | |||||||
Door*4 | Manually operated door with unlock button | |||||||
Heater | Strip wire heater | |||||||
Refrigeration unit | System*5 | Mechanical cascade refrigeration system | ||||||
Compressor | Hermetically sealed scroll compressor | |||||||
Expansion mechanism | Electronic expansion valve | |||||||
Refrigerant | High temp side:R404A, Low temp side R23 | |||||||
Cooler | Stainless steel welded plate heat exchanger | |||||||
Air circulator | Sirocco fan | |||||||
Damper driving unit | Air cylinder | |||||||
Fittings | Cable port with diameter 100mm on the left side (right side and tailor made diameter size are available as options), specimen power supply control terminal | |||||||
Inside dimensions (W x H x D) | 350 x 400 x 350 | 500 x 450 x 450 | Customized | |||||
Test area capacity | 50L | 100L | Customized | |||||
Test area load | 5 kg | 10 kg | Customized | |||||
Outside dimensions (W x H x D) | 1230 x 1830 x 1270 | 1380 x 1980 x 1370 | Customized | |||||
Weight | 800kg | 1100kg | N/A | |||||
Utility requirements
| Allowable ambient conditions | +5~30°C | ||||||
Power supply | AC380V, 50/60Hz, three phase , 30A | |||||||
Cooling water supply pressure*6 | 02~0.4Mpa | |||||||
Cooling water supply rate*6 | 8m³ /h | |||||||
Operating cooling water temp. range | +18 to 23 °C | |||||||
Noise Level | 70 dB or lower |
Safety Devices
1. Hot chamber overheat protection switch
2. Cold chamber overheat protection switch
3. Air circulator overload alarm
4. Refrigerator high/low pressure protector
5. Compressor temperature switch
6. Air pressure switch
7. Fuse
8. Water suspension relay ( water-cooled specification only)
9. Compressor circuit breaker
10. Heater circuit breaker
11. Test area overheat/overcool protector
12. Air purge valve
Copyright © 2017 Haida International Equipment Co., Ltd. | All Rights Reserved Design by www.allweyes.com Haida Subsite