Home  > Haida Products  > Battery Test Equipment  > EV Battery Safety Testing  >  Double Layer Battery Thermal Cycling Test Chamber
Haida Equiment Manufacturer

Haida Equiment Manufacturer has more than 15 years experience for test equipment...

Double Layer Battery Thermal Cycling Test Chamber

Double Layer Battery Thermal Cycling Test Chamber

Minimum
1 SET
Delivery
15 days after order.
Model
HD-H203-1
Country
China
BrandName
HD
Package
Each set protected with resin fiber and PP film, then put into Strong wooden case with operation manual and video inside.
Payment
L/C, D/P, T/T
Price
FOB, CIF

Double Layer Battery Thermal Cycling Test Chamber

STRUTURE 
 

2.1 Cooling System
1The refrigerating system uses environmentally friendly refrigerant R404a (R449a as option) and R23. Adopting binary low temperature circuit system design, it is convenient to use different compressors for work in different temperature regions.
2Temperature and humidity control using P.I.D + S.S.R system coordinated control with the same channel. It has the function of automatic calculation, which can immediately modify the temperature change conditions to make the temperature control more accurate and stable.
3High-precision controllers of temperature. The relative temperature performance is accurately set and displayed with a resolution of 0.1 ℃.
2.2 Temperature System
1Temperature system using Nickel-chromium alloy high-speed heating electric wire;
2High temperature system is completely independent;
3Contains four temperature sensors to detect the surface temperature of the battery and display it on the controller
2.3 Control System
Temp. SensorHigh precision PT100 Platinum resistance
ControllerWeintek
Display Functiona. Temp. Setting (SV) Practical (PV) value can be displayed directly
b. Display numbers, paragraphs, remaining time and cycles, running time
c. Program editing and graphic curve display,
d. Fixed or program operation status display,
Interfacea. RS-232 or R485 port design
b. Connected to computer
c. Monitor and remote control by computer and Ethernet
2.4 Protection System
1Protection for Electrical leakage
2Over-temperature
3Compressor overvoltage and overload
4Heater short circuit

MAIN TECHNICAL PARAMETERS 

 

3.1 Capacity and Material
ModelHD-E709-450
Test RoomWith 2 test area
Internal dimension for single test room(W*D*H)750*500*600 (225L)
Chamber External dimension(W*D*H)1150*1200*1850mm
Internal material1.0mm thickness SUS#304 stainless steel, Insulating material
External material1.0mm thickness cold-rolled steel plate baking
3.2 Temperature
Temperature Range-20℃ ~ + 150℃
Temperature fluctuation±0.5℃
Temperature uniformity≤2℃
Temperature RateCooling at 1℃/min in average (without loading)
Heating at 3℃/min in average (without loading)
3.3 Power Supply  
Power SourceThree-phase, AC380V,50Hz 
3.4 Cooling System and Others
CompressorSemi-Hermertically Sealed France Tecumseh / USA Copeland compressor
RefrigerantR404A
Cooling methodtwo-stage compression refrigeration system
Cooling methodAir-cooled flake condenser, cooling fan for heat dissipation
Heating SystemNichrome stainless steel heater
Testing holeDiameter 150mm, there are 2 holes for cable routing for each chamber
EvaporatorFinned tube heat exchanger
Dry filterAbsorb the residual moisture and acidic substances in the refrigerant of the refrigeration system, and filter out solid particles, copper shavings, etc. in the system to protect the normal operation of the expansion valve and capillary tube, and prevent ice blocking and dirty blocking.
Door handleNon-reaction, explosion-proof door handle, easy to operate, safe and reliable
Insulation100mm polyurethane rigid foam and 100mm high density glass fiber cotton
Insulation systemFilling the insulation area with ultra-fine glass fiber;
Machine connection parts are made of non-metal resistant high and low temperature materials, which effectively reduces the temperature conduction;
Door seal is made of refined silicone rubber, which is more reliable seal;
Observation windowDouble-layer vacuum-strengthened glass;
Heat-resistant defrosting on the inside with adhesive sheet conductive film, which can clearly observe inner chamber.
3.5Test Standard
1IEC6008-2-1 Cold
2IEC6008-2-2 Dry Heat
3IEC60068-2-38 Damp Heat, Cyclic




Leave a Message

Captcha

Loading verification code...

Please complete verification first

社媒暂无评论
Chat Online
Chat Online
Leave Your Message inputting...