    Product Description

    Single channel Differential-Pressure Air Tightness Tester judge air tightness by measuring the differential pressure on both sides of the test object. They are generally equipped with a pressure sensor and a differential pressure sensor. The pressure sensor measures the static pressure on both sides of the test object, while the differential pressure sensor measures the pressure difference between the two sides. The instruments generally require calibration to ensure accurate measurement.


    Principle: The differential pressure sensor can be piezoelectric or piezoresistive. It obtains the differential pressure value by measuring the force or deformation exerted by gas on the sensor.

    Single channel Differential-Pressure Air Tightness

    Product Specifications

    Model 5161-HD
    Instrument Type Direct-pressure
    Power supply AC 220 V/50Hz (±10%)
    Max power 50W
    Cabinet dimension(W*D*H) 30 x 37 x 30 cm  (Single channel)
    Cabinet material Precision sheet metal, 1.5mm carbon steel
    Cabinet surface High-gloss white, Plastic spraying outer surface
    Overall weight (Net weight) 13Kg (Single channel)
    Air supply pressure 0.2Mpa~1.0Mpa (Clean, dry, non-corrosive)
    Air supply medium Compressed air
    Air pressure stabilizer Two-stage (Filtration/pressure-reduction)
    Air intake port Φ8
    Test port Φ6
    Test quantity Single channel (test 1 products at a time)
    Test range (Max test range, subject to customer requirements) 5-700Kpa (Single positive pressure model)
    -70-0Kpa (Single negative pressure model)
    -70-700Kpa (Full-function model)
    Pressure adjustment mode Manual (Pressure regulation: Automatic pressure adjustment is custom-made)
    Pressure regulation accuracy (Pressure stabilization effect: sensor display accuracy<5pa) ≤200Pa (manual regulator)
    ≤1Kpa (auto regulator)
    Pressure mode Positive pressure (Only positive pressure test available)
    Negative pressure (Only negative pressure test available)
    Positive/negative pressure (Full-function model supports both)
    Sensor accuracy ≤0.1% F.S Full scale
    Differential pressure sensor accuracy ≤0.05% F.S
    Inflation speed 0.63dm3/(s·bar) Flow rate when pressure difference is 1 bar
    Resolution (Display accuracy) 0.1pa
    I/O contact I=4/O=8  (Single channel) Input: start/stop/raster/emergency stop. Output: pass/fail signal/DC24V,GND, also supports control of multiple relays
    RS232 1. Connect to supper computer for communication
    2. Connect to label printer
    1. Mudbus RTU standard protocol
    2. Auto generate QR codes, barcodes&characters with real-time test data
    USB port Support barcode scanners, USB flash drives, and mice.
    1. Scan QR & barcode, export historical records
    2. Scan-trigger test: auto-launch detection via scanner gun without pressing any buttons.
    Ethernet port Connect to upper computer for communication (TCP/IP standard protocol)
    Display screen 10.1-inch color LCD Widescreen (262K colors, 1024x600 resolution)
    Operation interface Touch-type (Human-machine interaction)
    Language Chinese/English
    Program quantity 120 group per channel (Freely switchable, custom program names supported)
    Test pressure unit 11 types (Pa N/m2 mbar hpa kpa bar Mpa psi ib/in mmHg Torr)
    Leakage value unit 10 types (Pa mmHg Torr mbar hpa kpa pa/s kpa/s pa/min kpa/min)
    Leakage rate unit 8 types (cm3/m3 sccm mL/min mL/s L/min mL/h L/h pa.m3/s)
    Judgment mode Automatic judgment with sound and light alarm
    Pass: Silent + Green Light
    Fail: Beeping sound + Red Light
    Historical data export Store up to 100,000 test records; USB export available (Automatically delete the earliest 20% of records when the maximum capacity is exceeded.)
    Inflation time 1-999999 seconds (Adjustable as required)
    Pressure holding time 1-999999 seconds (Adjustable as required)
    Testing Time 1-999999 seconds (Adjustable as required)
    Pressure mode Positive pressure (Positive pressure test)
    Negative pressure  (Negative pressure test)
    Test mode Direct (Direct product internal inflation test)
    Volume (External inflation test of the product, equal-pressure equal-volume test mode)
    Micro-trace (External inflation test of the product, equal-pressure equal-volume test mode)
    Pre-charging function (Only supports full-function positive and negative pressure instruments) Single positive pressure mode
    Single negative pressure mode
    Positive/Negative-pressure mode
    Usage environment
    Storage temperature -10℃~60℃
    Storage humidity 5%~90%(No condensation)
    Operating temperature 0℃~45℃
    Operating humidity 5%~90%(No condensation)
    Usage altitude ≤ 500 m

    Leave A Message

    You can also contact me via email. My email address is manager@qc-test.com
    Related Products

    HAIDA Test Equipment

    Vibration Shaker Table Systems
    Mask Making Machine
    Leather & Shoes Test Machine
    Luggage Test Equipment
    Optical Test Equipment
    Rubber and Plastic Test Equipment
    RoHS Testing Equipment
    Cookware Testing Equipment
    Car parts testing equipment

    Contact us

    Copyright © 2026 Haida International Equipment Co., Ltd. | Sitemap
    Contact us
    whatsapp
    Contact customer service
    Contact us
    whatsapp
    cancel
    Customer service
    detect